Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

LADDERLOGIX 6306f71c981554000164a40c Products https://www.ladderlogixindia.com
  • 2023-05-13T16:49:11

ESSENTIAL-PS/1AC/24DC/240W/EE - Power supply unit 2910587 #PhoenixSMPS AC operation Nominal input voltage range 100 V AC ... 240 V AC Input voltage range 85 V AC ... 264 V AC Derating < 100 V (1 %/V) Input voltage range AC 85 V AC ... 264 V AC Input voltage range DC 120 V DC ... 375 V DC Inrush current typ. 20 A (115 V AC) typ. 40 A (230 V AC) AC frequency range 47 Hz ... 63 Hz Mains buffering time typ. 10 ms (115 V AC) typ. 20 ms (230 V AC) Current consumption 2.8 A (115 V AC) 1.4 A (230 V AC) Nominal power consumption 273.22 VA Protective circuit Transient surge protection; Varistor Typical response time 1000 ms Input fuse 6.3 A (slow-blow, internal) Discharge current to PE < 1 mA (264) Efficiency 88 % (115 V AC) 90 % (230 V AC) Output characteristic HICCUP Nominal output voltage 24 V DC ±2 % Setting range of the output voltage (USet) 22 V DC ... 28 V DC (max. power ≤ 240 W) Nominal output current (IN) 10 A Derating > 40 °C (1.67 % / °C, 115 V AC) > 50 °C (2.5 % / °C, 230 V AC) Max. capacitive load 8000 μF Active current limitation 105% - 150% of the max. output power (in the event of short circuit) Control deviation ≤ 1 % (change in load, static 10 % ... 90 %) typ. ± 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple < 120 mVPP (-10 °C ... +70 °C) < 240 mVPP (-20 °C ... -10 °C) Output power 240 W Maximum no-load power dissipation 4.62 W (115 V AC) 2.14 W (230 V AC) Power loss nominal load max. 31.53 W (115 V AC) 25.44 W (230 V AC)

ESSENTIAL-PS/1AC/24DC/240W/EE - Power supply unit 2910587 #PhoenixSMPS AC operation Nominal input voltage range 100 V AC ... 240 V AC Input voltage range 85 V AC ... 264 V AC Derating < 100 V (1 %/V) Input voltage range AC 85 V AC ... 264 V AC Input voltage range DC 120 V DC ... 375 V DC Inrush current typ. 20 A (115 V AC) typ. 40 A (230 V AC) AC frequency range 47 Hz ... 63 Hz Mains buffering time typ. 10 ms (115 V AC) typ. 20 ms (230 V AC) Current consumption 2.8 A (115 V AC) 1.4 A (230 V AC) Nominal power consumption 273.22 VA Protective circuit Transient surge protection; Varistor Typical response time 1000 ms Input fuse 6.3 A (slow-blow, internal) Discharge current to PE < 1 mA (264) Efficiency 88 % (115 V AC) 90 % (230 V AC) Output characteristic HICCUP Nominal output voltage 24 V DC ±2 % Setting range of the output voltage (USet) 22 V DC ... 28 V DC (max. power ≤ 240 W) Nominal output current (IN) 10 A Derating > 40 °C (1.67 % / °C, 115 V AC) > 50 °C (2.5 % / °C, 230 V AC) Max. capacitive load 8000 μF Active current limitation 105% - 150% of the max. output power (in the event of short circuit) Control deviation ≤ 1 % (change in load, static 10 % ... 90 %) typ. ± 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple < 120 mVPP (-10 °C ... +70 °C) < 240 mVPP (-20 °C ... -10 °C) Output power 240 W Maximum no-load power dissipation 4.62 W (115 V AC) 2.14 W (230 V AC) Power loss nominal load max. 31.53 W (115 V AC) 25.44 W (230 V AC)

  • 2023-05-13T16:49:11

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us